SLOG-200E

SLOG-200E

SKU: SLOG-200E

SLOG-200E is a reusable ultra-low temperature data logger with an external PT100 probe for monitoring temperatures from -200°C to +70°C. Designed for cryogenic storage, ultra-low temperature freezers, laboratories and deep-frozen cold chains, it stores up to 52,000 readings and displays key monitoring information on its LCD. After monitoring, connect the logger to a computer USB port to generate an encrypted PDF report automatically. A replaceable battery supports repeated and long-duration use.

  • CE
  • EN12830
  • ISO9001
  • RoHs
  • IATA PI 970

Why Shipments Get Rejected

Temperature excursion
Missing proof of condition
Delayed data retrieval
Non-compliant reports

Technical Specifications

Technical Specifications+

Temperature Range

-200℃ ~ +70℃

Accuracy

±0.5°C

Data Storage

52,000

FAQ+

What temperature range do your loggers support?

Our product line covers ranges from -50°C to +100°C depending on the model. See individual product specifications for details.

Are your devices EN12830 certified?

Yes, selected models including TC-100 Pro and CS-50 carry EN12830 certification for European cold chain transport compliance.

Product Details

Ultra-Low Temperature Monitoring Down to -200°C

  • SLOG-200E is a reusable USB temperature data logger equipped with an external PT100 probe for cryogenic and ultra-low temperature monitoring from -200°C to +70°C.

  • The external probe measures the low-temperature environment while the logger body remains outside the monitored space. Users can check key information on the LCD and connect the logger to a computer after monitoring to generate an encrypted PDF report automatically.

Key Features:

External PT100 Probe

  • The PT100 probe provides stable temperature measurement across a wide range, making SLOG-200E suitable for ultra-low temperature freezers, cryogenic storage and deep-frozen applications.

Wide Measurement Range

  • Monitor temperatures from -200°C to +70°C with the external probe, covering applications from cryogenic environments to conventional refrigerated and controlled-temperature storage.

Instant Information on the LCD

  • Review the current temperature, recording status and alarm result directly on the built-in display without connecting the logger to a computer.

Encrypted PDF Report via USB

  • After monitoring is complete, connect SLOG-200E to a computer USB port to generate an encrypted PDF report automatically for quality review, traceability and record keeping.

Reusable with a Replaceable Battery

  • The replaceable CR2450 battery supports repeated monitoring and helps extend the service life of the logger.

Flexible Configuration

  • Configure recording intervals, start delay, temperature limits and other monitoring settings through the computer software before use.

Reliable Offline Recording

  • SLOG-200E records and stores data independently without relying on Bluetooth, Wi-Fi, cellular networks or cloud connectivity.

Temperature Information at a Glance

LCD Display:

  • Current temperature

  • Recording status

  • Normal or alarm status

  • Maximum temperature

  • Minimum temperature

  • Average temperature

  • Number of recorded readings

USB PDF Report:

  • Complete temperature history.

  • Temperature graph and recorded data.

  • Maximum, minimum and average temperature.

  • Alarm and excursion information.

  • Start and stop time.

  • Device identification and configuration.

  • Encrypted PDF format for secure record keeping.

How It Works:

  • Connect and position the PT100 probe in the monitored environment.

  • Keep the logger body within its specified operating temperature range.

  • Configure the logger through the computer software if required.

  • Press and hold the start button for three seconds.</li>

  • Confirm the recording status on the LCD.

  • Stop recording using the button or by connecting the logger to a computer.

  • Open the automatically generated PDF report from the USB drive.

Applications:

  • Ultra-low temperature freezers.

  • Cryogenic storage and transportation.

  • Biological samples and laboratory materials.

  • Cell, tissue and specimen storage.

  • Dry ice and deep-frozen cold chains.

  • Pharmaceutical and biotechnology laboratories.

  • Research and temperature-controlled equipment.

Important Placement Requirement

  • The -200°C to +70°C measurement range applies to the external PT100 probe. The logger body must not be placed outside its specified operating range. Position the probe in the ultra-low temperature environment while keeping the main device in a suitable location for operation and data access.

When Should You Choose SLOG-200E?

  • Choose SLOG-200E when temperatures below -30°C must be monitored and the logger can be retrieved for repeated use. Its external probe is suitable for fixed equipment, ultra-low temperature freezers and reusable transport systems.

  • For a compact logger designed to travel directly inside dry ice packaging, choose a CLOG ultra-low temperature data logger instead.

Recommended Products